- Plastic fan
- FRP fan
- Stainless steel fan
- Plastic acid mist purif
- FRP acid mist purificat
- Stainless steel tower
- Horizontal cross spray
- Activated carbon absorb
- Activated carbon fiber
- Organic waste gas purif
- Chemical waste gas puri
- Electroplating waste ga
- Painting (coating) wast...
- Electrophoresis paint e...
- Plastic granulation exh
- Rubber exhaust gas puri
- Ammonia gas purificatio
- Casting exhaust gas pur
- Deodorization purificat
- Cartridge type dust col
- Cyclone separator
- Pulsed jet cloth filter
- Dust-containing cycloni
- Water film dust catcher
- Ion-exchange water puri
- Reverse osmosis water p
- Hollow fiber membrane u...
- Waste incinerator
- Photolysis exhaust puri
- Catering fume purifier
- Waste gas purification ...
- By-product hydrochloric
- Purification equipment ...
- Corrosive solution filt
- Venturi jet device
- FRP septic tank
- Aerator, drainage cap,
- Environmental protectio
- Activated carbon, carbo...
- Plastic pipeline, pipe ...
- Plastic air pipe, air v...
- Corrosion prevention of...
- Plastic reaction kettle
- Plastic mixing tank
- Plastic tank
- Plastic vacuum metering
- Plastic vacuum suction
- FRP tank
- Plastic/FRP composite t
- Graphite modified polyp...
- Graphite modified PP tu...
- Stainless steel tower
- Stainless steel centrif
- Stainless steel tank
- Stainless steel reactor
- Stainless steel mixing
- Stainless steel heat ex
- Stainless steel drying
- Stainless steel ferment
- Automatic hanging-plati
- Automatic barrel-platin
- Spoke electroplating eq
- Semi-automatic barrel p
- Manual barrel plating e
- Manual hanging-plating
- Electroplating solution
- Electroplating power su
- Electroplating auxiliar
- Reinforced polypropylen
- All plastic water jet v
- Metal water jet vacuum
- Metal water jet vacuum
- Stainless steel water j
- Steam-water series wate
- Roots-water jet vacuum
- Water jet condensing pu
- Building drainage vacuu


Application range and structure:
Changjia SW series venturi jet device is widely used in aeration and sludge treatment in environmental protection sewage treatment project, ozone dosing, tail gas reuse, desulfuration by wet processes, and etc.
Specifications and technical parameters:
Specifications
Models
|
Power flow |
Inlet pressure |
Installed power |
Maximum air absorption capacity |
Under latn, maximum water absorption(m3/h) (density 1kg/L) |
Materials |
|
Lower suction port pressure latn |
Lower suction port pressure 1.6atn |
||||||
SW-200 |
7.5-33 |
0.35〜7.03 |
0.11-9 |
37 |
94 |
2.3 |
304/316 |
SW-300 |
17〜74 |
0.35〜7.03 |
0.3〜20 |
56 |
142 |
4.6 |
304/316 |
SW-400 |
30〜103 |
0.35〜4.22 |
0.5〜18 |
111 |
284 |
10.6 |
304/316 |
SW-800 |
82〜303 |
0.35〜4.92 |
1.5〜58 |
383 |
980 |
20 |
304/316 |
SW-1200 |
140〜480 |
0.35〜4.92 |
2〜92 |
608 |
1556 |
31.8 |
304/316 |
SW-3600 |
274-1010 |
0.35〜4.57 |
4-180 |
1277 |
3269 |
66.7 |
304/316 |